274 - AT-R02 | Technical Measurement & Evidence Traceability Register
Buy 4 Checklists, Get 1 Free
WHY THIS SOURCE MATTERS
Original AVC AT-R02 source Word is used for Testing, Inspection, NDT and Commissioning during non-nuclear power station or industrial outage work. The contractor must prove the actual testing or inspection state, correct asset, current permit and safety controls rather than inventing acceptance from an empty form.
WHEN TO USE THIS ACTUAL FORM
Use with real station or UNIT, work package and asset tag, DATE / SHIFT, authorised station or control-room custodian and the correct current permit or approved isolation. Confirm competency, instrument calibration, operation boundaries, simultaneous maintenance crews and the approved procedure before any testing. Stop if energy state, plant conditions or authorised scope changes.
VERIFIED ORIGINAL WORD FIELDS
The source Word genuinely contains 6 printed evidence-register columns. Examples from the actual original: Asset / test package; As-found / acceptance band; Instrument / cal. ID; As-left / result; NCR / concession; Witness / release.
SOURCE TEST AND SIGNATURE EVIDENCE
The genuine six-column register captures asset/test package, as-found result and acceptance band, calibrated instrument ID, as-left outcome, NCR/concession and witness/release. Preserve genuine test attachments, serial identification and discrepancy disposition.
INDEPENDENT PLANT OPERATIONS AUTHORITY
Station operations and appointed technical owners retain sole authority for isolation, switching, high-energy testing and facility release. A contractor inspector signature, crew talk or measurement register cannot energise or return any asset to service. Missing results, invalid calibration, unaccepted NCR or an absent witness remains HOLD until competent disposition.
REVIEW, TEST AND SHIFT HANDOVER
At a shift change, reconcile all temporary supplies, jumpers, blinds, barriers, test instruments, guards and foreign objects. Record real anomalies and acceptance limits, the named reviewer, revised permit, evidence and the separate station handover reference. Preserve failed/out-of-band findings and implement approved corrective action before controlled continuation.
SOURCE WORD AND AVC BUNDLES
This true source-identical editable AVC Word is R12.95 individually; the exact source is already included in the 277-form Power Generation & Outage Checklist Package and full 525-page Contractor H&S File. Avoid duplicate buying. Eligible individual Singles may qualify for BUY 4 GET 1 FREE while the automatic cart offer applies: five pay for four, ten for eight, fifteen for twelve. Confirm checkout; full packages excluded.

